Power using mean squared error (MSE)
It calculates power for the bioequivalence test on ratio using mean squared error (MSE).
powmse(n, mse, DesignNo = 1, True.R = 1, Alpha = 0.1, ThetaL = 0.8, ThetaU = 1.25)
n |
Sample size, n per group |
mse |
Mean squared error |
DesignNo |
Crossover design number. Design Number (treatment x sequence x period) 1 2x2x2 : RT TR (no carry-over) 2 2x4x2 (Balaam Design) : TT RR RT TR (no carry-over) 3 2x2x3 (Two-sequence Dual Design): TRR RTT (no carry-over) 4 2x3x3 : TRR RTR RRT - carry-over effect 5 2x2x4c : TRRT RTTR + carry-over effect 6 2x2x4 : TRRT RTTR - carry-over effect 7 2x4x4 : TTRR RRTT TRRT RTTR 8 3x6x3c (William Design for 3 treatments) + carry-over effect : RBA ARB BAR ABR BRA RAB 9 3x6x3 (William Design for 3 treatments) - carry-over effect : RBA ARB BAR ABR BRA RAB 10 4x4x4c (William Design for 4 treatments) + carry-over effect : RCAB ARBC BACR CBRA 11 4x4x4 (William Design for 4 treatments) - carry-over effect : RCAB ARBC BACR CBRA |
True.R |
True ratio of test/reference |
Alpha |
Alpha error level |
ThetaL |
Lower limit of equivalence criteria |
ThetaU |
Upper limit of equivalence criteria |
It calculates power of sample size (n per group) with mse
.
Returns power [0, 1))
Kyun-Seop Bae k@acr.kr
powmse(12, 0.06)
Please choose more modern alternatives, such as Google Chrome or Mozilla Firefox.